{{ $t('shop.all.spaetbestellservice.hinweis') }}
Dimensions W x L x H |
50 mm x 107 mm x 55 mm, (Incl. linking block and connectors) |
Diagnosis |
Unterspannung Ventile, Drahtbruch pro Kanal, Kurzschluss/Überlast pro Kanal, Querschluss |
Parameterising |
Diagnoseverhalten, Überwachung Drahtbruch/Kanal |
LED displays |
1 Failsafe-Protokoll aktiv, 1 Sammeldiagnose, 3 Kanaldiagnose, 3 Kanalstatus |
Intrinsic power input at operating voltage |
Type 25 mA (operating voltage supply electronics), Type 65 mA (Load voltage supply valve) |
Max. power supply per channel | 1.5 A |
Nominal operating voltage DC [V] | 24 |
Potential separation channel - internal bus | Yes, for intermediate feed |
Potential separation channel - channel | no |
Corrosion resistant class KBK |
(In integrated condition), 1 - low corrosion stress |
Bearing temperature [°C] | -20 to 70 |
Protection category | Depends on connection block |
ambient temperature [°C] | -5 to 50 |
Product weight [g] | 50,0 |
Max. address volume outputs [Byte] | 6 |
Max. address volume inputs [Byte] | 6 |
Max. line length | 200 m |
Material information | RoHs compliant |
Housing material |
PC, PA reinforced |
Fuse (short circuit) | Internal electronic fuse Per channel |
Quantity outputs: | 2 |
Switching logic outputs | PM switching |
Safety function | Securely switch off the supply voltage of the valves |
Safety Integrity Level (SIL) | Safe switch off / SIL 3 |
Performance Level (PL) | Safety assembly category 3 performance level e |
Load capacity against functional ground [nF] | 400 |
Max. reaction time on switch off command | F_WD_TIME + 23 ms |
Max. cumulative currents per module [A] | 5 |
residual ripple | 2 Vss within voltage range |
Voltage drop per channel [V] | 0,6 |
Permitted voltage oscillations | -15 % / +20 % |
Permission | c UL us - Recognized (OL) |
CE certificate (see declaration of conformity) | to EU machinery directive |
Certified awarding point | TÜV Rheinland 01/205/5294.01/18 |
Information about ambient temperature | Derating-Kurve für Pneumatik-Anschaltung beachten |
Probability of Failure per Hour in [1/h]. | 1e-009 |
Information about outputs |
1 internal channel to switch off valve voltage, 2 external outputs |
{{ $t('shop.all.gewicht') }} | 50,0 g / pcs |
{{ $t('shop.display.artikel.zollwarennummer') }} | 85389099 |
{{ $t('shop.all.hersteller') }} | Festo |
{{ $t('shop.all.spaetbestellservice.hinweis') }}
{{ $t('shop.all.wochenendversand.hinweis') }}
An error has occurred, please reload this page and try again.